Without using M-MDS
- Remove the battery cover. (See BATTERY REMOVAL/INSTALLATION .)
- Disconnect the negative battery cable. (See BATTERY REMOVAL/INSTALLATION .)
- Short the check connector terminal F/P to ground using a jumper wire.
- Connect the negative battery cable. (See BATTERY REMOVAL/INSTALLATION .)
- Turn the ignition switch to the ON position to operate the fuel pump.
- Verify that there is no fuel leakage from the pressurized parts.
Standard
There shall be no leakage after 5 min.
- In the case of fuel leakage, replace the following components and then do the recheck by the fuel leakage checking procedure.
- If there is leakage, replace the fuel hoses and clips.
- If there is damage on the seal on the fuel pipe side, replace the fuel pipe.