No. 2 Additional Key Programming Procedure (Using the M-MDS): Procedure
Courtesy of MAZDA MOTORS CORP. ADDITIONAL KEY PROGRAMMING PROCEDURE CHART
| Step |
Procedure |
Action after procedure |
| 1 |
PERFORM ADDITIONAL KEY PROGRAMMING
- Connect the M-MDS to the DLC-2. (See
M-MDS CONNECTING PROCEDURE )
- Turn the ignition switch to the ON position using key 1.
NOTE:
- Although the security light starts flashing and DTC 15 is displayed after approx. 1 min
, this does not indicate an improper procedure. Continue to perform the procedure as indicated.
- After vehicle identification, select the following from the M-MDS initial screen.
- Using an IDS (laptop PC)
- Select "Body".
- Select "Security".
- Select "PATS Functions".
- Using a PDS (pocket PC):
- Select "Programming".
- Select "PATS Functions".
- Then, select an item from the screen menu.
- Program additional ignition key
- Perform the security access according to the directions on the M-MDS screen.
NOTE:
- After executing the above menu, "This operation is successful" is displayed. This indicates that the programming of the key currently in the ignition switch ON position has been completed.
- After verifying that the PATS function menu is displayed again on the M-MDS screen, turn the ignition switch to the LOCK position.
- Remove key 1.
- Are there other keys to be programmed?
|
Yes |
Change the key and repeat Step 1.
NOTE:
- Additional key programming can be performed using the procedure in No. 1 Additional Key Programming Procedure (Using Two Valid Keys).
|
| No |
Go to the next step. |
| 2 |
CLOSE THE M-MDS
- After verifying that the PATS function menu is displayed again on the M-MDS screen, select "Finish (this menu)".
- Turn the ignition switch to the LOCK position.
|
Go to the next step. |
| 3 |
VERIFY KEY PROGRAMMING IS CORRECT Verify that the engine can be started with the programmed key.
NOTE:
- When verifying that the engine starts, wait at least approx. 5 s or more
before starting the engine using the next key.
|
Procedure is completed |