LEMON Manuals: Even more car manuals for everyone
Home >> Mazda >> 2014 >> MX-5 Miata Club, Automatic Trans >> Repair and Diagnosis >> Body & Frame >> Door Locks >> On-Board Diagnostic [Advanced Keyless Entry System] >> DTC U0214 [Advanced Keyless And Start System] >> Diagnostic Procedure

Diagnostic Procedure

DTC U0214 DIAGNOSTIC PROCEDURE

STEP INSPECTION ACTION
1 INSPECT WIRING HARNESS BETWEEN KEYLESS RECEIVER AND GROUND 
  • Disconnect keyless receiver connector.
  • Is there continuity between keyless receiver terminal E and ground?
Yes Go to next step.
No
  • Repair the wiring harness between the keyless receiver and ground.
  • Go to next step.
2 INSPECT COMMUNICATION CIRCUIT FOR CONTINUITY 
  • Disconnect keyless control module connector and keyless receiver connector.
  • Inspect the continuity between the following connector terminals.
    • keyless control module: 3S-keyless receiver: A
    • keyless control module: 3U-keyless receiver: C
  • Is there continuity?
Yes Go to next step.
No
  • Repair the wiring harness between the keyless receiver and keyless control module.
  • Go to next step.
3 INSPECT KEYLESS RECEIVER POWER SUPPLY CIRCUIT 
  • Turn ignition switch to ON position.
  • Measure voltage at terminal 3S of keyless control module connector.
  • Is voltage more than 7.5 V? 
Yes Replace keyless receiver.
(See KEYLESS RECEIVER REMOVAL/INSTALLATION )
No Replace the keyless control module and perform the resetting procedure for the advanced keyless system when replacing the keyless control module.
(See KEYLESS CONTROL MODULE REMOVAL/INSTALLATION )
(See ADVANCED KEY ID CODE REGISTRATION )
(See STEERING LOCK UNIT ID CODE REGISTRATION )
(See KEYLESS CONTROL MODULE CONFIGURATION )
(See IMMOBILIZER SYSTEM-RELATED PARTS PROGRAMMING [KEYLESS ENTRY SYSTEM] )