Up Switch Inspection
CAUTION:
- Water or foreign objects entering the connector can cause a poor connection or corrosion. Be sure not to drop water or foreign objects on the connector when disconnecting it.
- Do not damage the terminals.
- Disconnect the selector lever component connector.
- Disconnect the negative battery cable.
- Remove the console. (See CONSOLE REMOVAL/INSTALLATION .)
- Disconnect the selector lever component connector.
- Measure the continuity between selector lever component terminals A and D.
- If there is any malfunction, replace the selector lever component. (See AUTOMATIC TRANSAXLE SHIFT MECHANISM REMOVAL/INSTALLATION .)
UP SWITCH SPECIFICATIONTest condition Continuity M (+) Continuity Except M (+) No continuity