LEMON Manuals: Even more car manuals for everyone
Home >> Mazda >> 2013 >> CX-5 Sport, FWD, Automatic Trans >> Repair and Diagnosis >> Electrical >> Horns >> Instrumentation/Driver Info >> Clock Input/Output Check Mode >> Inspection

Clock Input/Output Check Mode: Inspection

NOTE:
  • The clock input/output check mode is displayed in the following order and returning to the previous screen is impossible.
  • If you want to check All LCD illuminated or Check code 1 or 2 after Check code 6 is displayed, activate the input/output check mode again.
Item Check content
All LCD illuminated LCD indication
Check code 1 MS-CAN BUS OFF occurrence
Check code 2 Communication between instrument cluster
Check code 6 Ignition switch ON/OFF signal
ALL LCD ILLUMINATED

Inspection Display Action
  • Activate the clock input/output check mode.
  • Are all segments and dots on the LCD illuminated?
G09077882
Yes LCD display is normal.
No Replace the clock. (See CLOCK INSPECTION ).
INSPECTION PROCEDURE - CHECK CODE 1

Inspection procedure Display Action
  1. Press the H button to display check code 1.
  2. Verify the screen display.
G09077883
There is no MS-CAN BUS OFF error (normal)
G09077884
There is an MS-CAN BUS OFF error (malfunction)
Perform the malfunction diagnosis for the MS-CAN referring to the following:
(See FOREWORD ).
INSPECTION PROCEDURE - CHECK CODE 2

Inspection procedure Display Action
  1. Press the H button to display check code 2.
  2. Verify the screen display.
G09077885
There is no communication error between the instrument cluster.
G09077886
There is a communication error between the instrument cluster.
Perform the malfunction diagnosis for the MS-CAN referring to the following:
(See FOREWORD ).
INSPECTION PROCEDURE - CHECK CODE 6

Inspection procedure Display Action
Step 1
  1. Press the H button to display check code 6.
  2. Switch the ignition ON (engine off or on).
  3. Verify the screen display.
G09077887
Go to the next step.
G09077888
Refer to the clock inspection and verify the terminal voltage at clock terminal A.
(See CLOCK INSPECTION ).
  • Replace the clock if the voltage is B+. (See CLOCK REMOVAL/INSTALLATION ).
  • Inspect the following parts if the voltage is 1.0 V or less.
    • METER1 10 A fuse
    • IG relay
    • Related wiring harness
Step 2
  1. Switch the ignition off (LOCK).
  2. Verify the screen display.
G09077889
Ignition switch ON/OFF signal is normal.
G09077890
Refer to the clock inspection and verify the terminal voltage at clock terminal A.
(See CLOCK INSPECTION ).
  • Replace the clock if the voltage is 1.0 V or more. (See CLOCK REMOVAL/INSTALLATION ).
  • Inspect the following parts if the voltage is B+.
    • METER1 10 A fuse
    • IG relay
    • Related wiring harness