| 1 |
INSPECT FOR MALFUNCTION IN BCM POWER SUPPLY CIRCUIT OR ELSEWHERE
- Did any of the following items operate during the keyless entry system operation inspection?
- All doors lock/unlock
- Turn signal/hazard warning indicator light flashes
|
Yes |
Go to the next step. |
| No |
Inspect the connection of the BCM connectors, and go to Step 4. |
| 2 |
INSPECT FOR MALFUNCTION IN KEY REMINDER SWITCH OR ELSEWHERE
- Did the following item operate during the keyless entry system operation inspection?
|
Yes |
Go to the next step. |
| No |
Go to Step 8. |
| 3 |
INSPECT FOR MALFUNCTION IN DOOR LOCK ACTUATOR OR ELSEWHERE
- Did the following item operate during the keyless entry system operation inspection?
- Turn signal/hazard warning indicator light flashes
|
Yes |
Go to the next step. |
| No |
Go to Step 10. |
| *4 |
INSPECT BCM POWER SUPPLY CIRCUIT
- Are the BCM power supply and voltage normal?
- IG1 signal (terminal 4T)
- B+ signal (terminal 3J, 5B, 4S, 4A)
|
Yes |
Go to the next step. |
| No |
- Inspect for blown fuse.
- Inspect the power supply system wiring harness for an open or short circuit.
- Then go to Step 13.
|
| *5 |
INSPECT BCM GROUND CIRCUIT
- Is the BCM ground voltage normal?
- 1.0 V or less
(terminal 2N, 4B)
|
Yes |
Go to the next step. |
| No |
Inspect the ground system wiring harness for open circuit. Then go to Step 13. |
| *6 |
INSPECT IF MALFUNCTION IS IN DOOR, LIFTGATE LATCH SWITCH SIGNALS OR ELSEWHERE
- Monitor following BCM (door, liftgate latch switch) PID using the M-MDS.
- TR/LG_SW (Liftgate latch switch)
- DRSW_P (Passenger's door latch switch)
- DRSW_D (Driver's door latch switch)
- DRSW_LR (Sliding door switch (LH))
- DRSW_RR (Sliding door switch (RH))
- Are monitored PID values normal?
|
Yes |
Go to the next Step. |
| No |
- Inspect for open or short circuit in wiring harness between BCM and suspected door latch switch, sliding door switch, and the liftgate latch switch.
Then go to Step 13. |
| 7 |
INSPECT KEY REMINDER SWITCH
- Measure the voltage at the following BCM terminals:
- Is the key reminder switch normal?
|
Yes |
Replace the BCM. |
| No |
Replace the key reminder switch, then go to Step 13. |
| 8 |
INSPECT IF MALFUNCTION IS IN DOOR LOCK ACTUATOR, BCM GROUND CIRCUIT OR ELSEWHERE
- Measure the voltage at the BCM terminals 5O, 5M and 5K while operating the keyless entry remote transmitter.
- ALL door unlocked: B+ → 1.0 V or less
(Normal unlock: 5M terminal)(2-step unlocking: 5K terminal)
- ALL door locked: B+ → 1.0 V or less
(5O terminal)
|
Yes |
Go to the next step. |
| No |
- Inspect the wiring harness between BCM and the door lock actuator for an open or short circuit.
- Inspect the door lock actuator.
- Then go to Step 13.
|
| 9 |
INSPECT DOOR LOCK LINKAGE
- Operate the key cylinder and verify the door locks and unlock manually.
- Does every door lock system work?
|
Yes |
Go to step 12. |
| No |
Inspect the door lock linkage then go to Step 13. |
| 10 |
INSPECT FOR MALFUNCTION IN THEFT-DETERRENT SYSTEM OR ELSEWHERE
- Is the theft-deterrent system equipped?
|
Yes |
Go to the next step. |
| No |
Go to step 12. |
| 11 |
INSPECT HOOD LATCH SWITCH AND LIFTGATE SIGNAL
- Monitor following BCM PID using the M-MDS.
- TR/LG_SW (liftgate latch switch)
- HOOD_SW (hood latch switch)
- Are monitored PID values ON (open)?
|
Yes |
Normal operation (Turn signal/hazard warning indicator light flashing on vehicles with theft-deterrent system operates in conjunction with theft-deterrent system). |
| No |
Go to the next step. |
| 12 |
INSPECT TURN LIGHT SIGNAL CIRCUIT
- Measure voltage at the BCM terminals 5C, 3L (right side turn signal), 5E, 3K (left side turn signal) while operating hazard and/or turn signal on.
- Are the terminal voltages are alternated between 1.0V or less and B+?
|
Yes |
Verify the malfunction symptom again. |
| No |
- Inspect the wiring harnesses between the BCM and each turn light for a short circuit.
- Inspect each turn light.
- If these items are normal, replace the BCM.
|
| 13 |
REINSPECT MALFUNCTION SYMPTOM AFTER REPAIR
- Does the keyless entry system operate properly?
|
Yes |
Troubleshooting completed. Explain repairs to the customer. |
| No |
Reinspect the malfunction symptoms, then repeat from Step 1 if the malfunction recurs. |