DESCRIPTION 
  • Short to ground in starter circuit
DETECTION CONDITION 
  • Detect that the voltage of starter monitor is lower than the specification.
    • Starter monitor input circuit voltage less than 4.3 V  is detected under the following conditions:
      • IG1 relay output circuit is not active
      • Clutch is depressed
POSSIBLE CAUSE 
  • Starter relay malfunction
  • Connector or terminal malfunction
  • Short to ground in related wiring harness
  • PCM malfunction
  • Keyless control module malfunction