Panel Light Control Switch Inspection: Notes
- Connect the panel light control switch connector.
- Connect the negative battery cable.
- Measure the voltage at each terminal.
- If the voltage is not as specified in the Terminal Voltage Table (Reference) , inspect the parts under "Inspection item(s)".
- Disconnect the panel light control switch connector.
- If there is any malfunction, inspect the parts under "Inspection item(s)".
- If the system does not work properly even though the parts or related wiring harnesses do not have any malfunction, replace the panel light control switch.