Continuity Inspection
- Disconnect the negative battery cable.
- Disconnect the fuel pump unit connector.
- Inspect for continuity between fuel pump unit connector terminals B and D.
- If there is no continuity, replace the fuel pump unit. (See FUEL PUMP UNIT REMOVAL/INSTALLATION .)
- If as specified, carry out the "Circuit Open/Short Inspection ".