Continuity Inspection
- Remove the battery cover. (3 BATTERY REMOVAL/INSTALLATION [13B-MSP] .)
- Disconnect the negative battery cable.
- Disconnect the CPP switch connector.
- Verify that the continuity between CPP switch terminals B and D is as indicated in the table.
- If there is no malfunction, perform the "Circuit Open/Short Inspection". (See CIRCUIT OPEN/SHORT INSPECTION .)
- If there is any malfunction, replace the CPP switch. (Refer to the CLUTCH REMOVAL/INSTALLATION in the appropriate Clutch article. .)
CONTINUITY REFERENCE CHART
| Measurement condition | Clutch pedal position | Continuity |
|---|---|---|
| Push the rod | Clutch pedal released | No continuity |
| Except above | Clutch pedal depressed | Continuity detected |