Variable Swirl System Operation Inspection
- Access the ECT PID using the M-MDS. (See ON-BOARD DIAGNOSTIC TEST ).
- Verify that the ECT PID is below 0 °C {32 °F} .
- Start the engine.
- Inspect the rod operation under the following conditions:
ROD OPERATION
| Engine speed | 3, 250 rpm | |
|---|---|---|
| Below | Above | |
| Shutter valve actuator | Operate | Not operate |
If the rod operation is not specified, inspect as follows:
- Perform the KOER self test using the M-MDS and verify that the DTCs P2004:00, P2006:00, P2009:00 or P2010:00 is not displayed. (See
KOEO/KOER SELF TEST
).
- If the DTC P2004:00, P2006:00, P2009:00 or P2010:00 is displayed, perform DTC inspection. (See DTC P2004:00 ). (See DTC P2006:00 ). (See DTC P2009:00 ). (See DTC P2010:00 ).
If simulation function of M-MDS is used:
- Switch the ignition to ON (engine off).
- Turn the variable swirl solenoid valve from off to on using the IMRC PID and verify that the operation sound of the solenoid valve is heard.
- If the operation sound is not heard, replace the variable swirl solenoid valve. (See VARIABLE SWIRL SOLENOID VALVE INSPECTION ).
- If the operation sound is not heard, inspect the following:
- Vacuum hose and vacuum chamber for looseness or damage
- Variable swirl shutter valve actuator (See VARIABLE SWIRL SHUTTER VALVE ACTUATOR INSPECTION ).
- Check valve is stuck open or closed.
- Shutter valve cannot move smoothly.
If simulation function of M-MDS is not used:
- Inspect the variable swirl solenoid valve. (See
VARIABLE SWIRL SOLENOID VALVE INSPECTION
).
- If the variable swirl solenoid valve is not normal, replace the variable swirl solenoid valve. (See INTAKE-AIR SYSTEM REMOVAL/INSTALLATION ).
- If the variable swirl solenoid valve is normal, inspect the following:
- Vacuum hose and vacuum chamber for looseness or damage
- Variable swirl shutter valve actuator (See VARIABLE SWIRL SHUTTER VALVE ACTUATOR INSPECTION ).
- Check valve is stuck open or closed.
- Shutter valve cannot move smoothly.