| 1 |
PERFORM ADDITIONAL KEY PROGRAMMING
- Connect the M-MDS to the DLC-2.
(See
M-MDS CONNECTING PROCEDURE )
- Switch the ignition to ON using key 1.
NOTE:
- Although the security light starts flashing and DTC 15 is displayed after approx. 1 min
, this does not indicate an improper procedure. Continue to perform the procedure as indicated.
- After the vehicle is identified, select the following items from the initialization screen of the M-MDS.
- Using an IDS (laptop PC):
- Select "Body".
- Select "Security".
- Select "PATS Functions".
- Using a PDS (Pocket PC):
- Select "All Tests and Calibrations".
- Select "PATS Functions".
- Then, select an item from the screen menu.
item
- Program Additional Ignition Key.
- Perform the security access according to the directions on the M-MDS screen.
NOTE:
- After executing the above menu, This "operation is successful" is displayed. This indicates that the programming of the key that currently has the ignition switched on is completed.
- After verifying that the PATS function menu is displayed again on the M-MDS screen, switch the ignition off.
- Remove key 1.
- Are there other keys to be programmed?
|
Yes |
Change the key and repeat Step 1.
NOTE:
- Additional key programming can be performed using the procedure in No. 1 Additional Key Programming Procedure (Using Two Valid Keys).
|