EGR Control System Inspection
- Crank the engine and verify that EGR valve operation (initial operation) sound is heard.
- If the operation sound is not heard, connect the M-MDS to the DLC-2 and verify that the DTC P0403:00 is shown. Perform DTC inspection (See
DTC TABLE [L5]
.)
- Start the engine and idle it
- Warm up the engine to normal operating temperature
- Access the following PIDs:
- ECT, RPM, SEGRP_DSD, APP1, APP2, VSS
- Idle the vehicle and verify that the SEGRP value is 0
- Put the vehicle in drive
- Depress the accelerator pedal and verify that the SEGRP_DSD value is increased.
- If the EGR valve increases, inspect the following:
- EGR valve (stuck open or close)
- Wiring harness and connectors (Main relay - EGR valve - PCM)
- If the SEGRP_DSD value does not increase, inspect the VSS, APP1, APP2, TP_REL and ECT PIDs. (See
PCM INSPECTION [L5]
.)
- Stop the vehicle and verify that the SEGRP value returns to 0.