Wastegate Control System Operation Inspection
If simulation function of M-MDS is used:
- Start the engine and run it is idling.
- Disconnect the hose between the wastegate control solenoid valve and the intake pipe.
- Put a finger to the wastegate control solenoid valve and verify that there is no pressure applied.
- If there is pressure, inspect the following:
- Wiring harness and connectors (Wastegate control solenoid valve-PCM terminal 2AA)
- Wastegate control solenoid valve (stuck open) (See WASTEGATE CONTROL SOLENOID VALVE INSPECTION .)
- If there is pressure, inspect the following:
- Warm up the engine to normal operating temperature.
- Verify that the DTC P0245:00 or P0246:00 are shown. (See
ON-BOARD DIAGNOSTIC TEST
.)
- If the DTC P0245:00 or P0246:00 are shown, perform the DTC inspection. (See DTC P0245:00 .) (See DTC P0246:00 .)
- Access the WGC PID using the M-MDS. (See ON-BOARD DIAGNOSTIC TEST .)
- Increase the duty value of the wastegate control solenoid valve and inspect if the operation sound of the solenoid valve is heard.
- If the operation sound is heard, inspect for loose or damaged vacuum hoses. (Wastegate actuator-Wastegate control solenoid valve-Intake hose)
- If the operation sound is not heard, inspect the wastegate control solenoid valve. (See WASTEGATE CONTROL SOLENOID VALVE INSPECTION .)
- Warm up the engine to normal operating temperature.
- Access the WGC and APP PIDs using the M-MDS. (See ON-BOARD DIAGNOSTIC TEST .)
- Run the engine with the APP PID above 30%
and verify that the WGC PID value increases from 0%.
- If the WGC PID is 0% , inspect the APP PID. (See PCM INSPECTION .)
If simulation function of M-MDS is not used:
- Start the engine and run it is idling.
- Disconnect the hose between the wastegate control solenoid valve and the intake pipe.
- Put a finger to the wastegate control solenoid valve and verify that there is no pressure applied.
- If there is pressure, inspect the following:
- Wiring harness and connectors (Wastegate control solenoid valve-PCM terminal 2AA)
- Wastegate control solenoid valve (stuck open) (See WASTEGATE CONTROL SOLENOID VALVE INSPECTION .)
- If there is pressure, inspect the following:
- Warm up the engine to normal operating temperature.
- Verify that the DTC P0245:00 or P0246:00 are shown. (See
ON-BOARD DIAGNOSTIC TEST
.)
- If the DTC P0245:00 or P0246:00 are shown, perform the DTC inspection. (See DTC P0245:00 .) (See DTC P0246:00 .)
- Warm up the engine to normal operating temperature.
- Access the WGC and APP PIDs using the M-MDS. (See ON-BOARD DIAGNOSTIC TEST .)
- The hose between the wastegate control solenoid valve and intake pipe is disconnected.
- Run the engine with the APP PID above 30%
and verify that the WGC PID value increases from 0%
and there is pressure applied.
- If the WGC PID is 0% , inspect the TP REL PID. (See PCM INSPECTION .)
- If there is no pressure applied, inspect for the following:
- Wastegate control solenoid valve (stuck closed) (See WASTEGATE CONTROL SOLENOID VALVE INSPECTION .)
- Hose connection (Intake hose (turbocharger compressor downstream side)-Wastegate actuator-Intake hose (turbocharger compressor upstream side))