  1. Measure the voltage at each terminal (except terminals K and M.)
    • If the voltage is not as specified in the terminal voltage table, inspect the parts under Inspection item (s) and related wiring harnesses.
  2. Connect the negative battery cable.
  3. Inspect the power window main switch connector for continuity at terminals K and M.
  4. If the system does not work normally even though the inspection items or related wiring harnesses do not have any malfunction, replace the power window main switch.

    Go to TERMINAL VOLTAGE REFERENCE .

    Fig 1: Identifying Power Window Main Switch Connector
    G05985820Courtesy of MAZDA MOTORS CORP.
    TERMINAL VOLTAGE REFERENCE

    Terminal Signal name Connected to Measured condition Voltage (V)/Continuity Inspection item (s)
    A Close output Power window motor While door glass is opening 1.0 or less Power window motor
    While door glass is closing B+
    B Power cut Power window subswitch
    • Ignition switch at ON
    • Power cut switch at off
    0.25
    • Related wiring harness
    • Power window subswitch
    Ignition switch at ACC or LOCK 1.0 or lass
    Power cut switch at on 1.0 or less
    C Power supply Power window motor Ignition switch at ON B+ Power window motor
    E Power supply PAW 30 A fuse Under any condition B+ P/W 30 A fuse
    H Serial 1 Power window sub switch
    • Because this terminal is for communication, good/no good judgment by terminal voltage is not possible.
    • Inspect the wiring harness between power window main switch terminal H and power window subswitch terminal B for the following:
    • Short to ground
    • Open circuit
    Power window subswitch
    K GND Body ground Under any condition: Inspect for continuity to ground Continuity detected GND
    M GND Power window motor Under any condition: Inspect for continuity to ground Continuity detected Power window motor
    N IG2 Ignition relay Ignition switch at ON B+ Ignition relay
    Ignition switch at ACC or LOCK 1.0 or less
    O Pulse 1 Power window motor Door glass moving Approx. 6 Power window motor
    Door glass stopped 0 or B+
    P Pulse 2 Power window motor Door glass moving Approx. 6 Power window motor
    Door glass stopped 1.0 or less
    Q Open output Power window motor While door glass is opening B+ Power window motor
    While door glass is closing 1.0 or less
    R Perial 2 Keyless control module
    • Because this terminal is for communication, good/no good judgment by terminal voltage is not possible.

      Vehicles without advanced keyless system 

    • Inspect the wiring harness between power window main switch terminal R and keyless control module terminal 2T for the following:
      • Short to ground
      • Open circuit

      Vehicles with advanced keyless system 

      • Inspect the wiring harness between power window main switch terminal R and keyless control module terminal 2P for the following:
      • Short to ground
      • Open circuit
    Keyless control module
  5. Turn the ignition switch to ON position, and verify the LED illuminates.