Without Exterior Open function (Without Power Retractable Hardtop)
- Measure the voltage at each terminal.
- If the voltage is not as specified in the Terminal Voltage Table, inspect the parts under "Inspection item (s)" and related wiring harnesses.
- If the system does not work properly even though the inspection items or related wiring harnesses do not have any malfunction, replace the power window main switch.TERMINAL REFERENCE CHART
Terminal Signal name Connected to Measured condition Voltage (V) Inspection item (s) A Close output Power window motor (RH) While door glass is opening 1.0 or less - Power window motor (See POWER WINDOW MOTOR INSPECTION )
- Related wiring harnesses
While door glass is closing B+ B Open output Power window motor (LH) While door glass is opening B+ - Power window motor (See POWER WINDOW MOTOR INSPECTION )
- Related wiring harnesses
While door glass is closing 1.0 or less D Open output Power window motor (RH) While door glass is opening B+ - Power window motor (See POWER WINDOW MOTOR INSPECTION )
- Related wiring harnesses
While door glass is closing 1.0 or less G Close output Power window motor (LH) While door glass is opening 1.0 or less - Power window motor (See POWER WINDOW MOTOR INSPECTION )
- Related wiring harnesses
While door glass is closing B+ I IG1 - P.WIND 20 A fuse
- Ignition relay
Switch the ignition to ON B+ - P.WIND 20 A fuse
- Ignition relay
- Related wiring harnesses
Switch the ignition to LOCK 1.0 or less J GND Body ground Under any condition 1.0 or less - GND