Possible Causes
- Output circuit short to ground or voltage
- SJB
CAUTION:
- If DTC B106F is present and the SJB is to be replaced, the fault condition must be corrected first. Failure to correct the fault condition first may cause damage to the new SJB, resulting in a repeat repair.
DTC B106E - SOLID STATE DRIVER DISABLED DUE TO SHORT CIRCUIT - PINPOINT TEST REFERENCE
| PINPOINT TEST 1 | DTC B106E - SOLID STATE DRIVER DISABLED DUE TO SHORT CIRCUIT | ||
|---|---|---|---|
| STEP | INSPECTION | ACTION | |
| 1 | REVIEW THE DTCs
Are only DTC B106E and DTC B106F present? |
Yes | Install a new SJB. See Smart Junction Box (SJB) , . Test the system for normal operation. |
| No | CORRECT any DTCs present other than DTC B106E and DTC B106F. After the repair, go to next step. | ||
| 2 | CARRY OUT THE SJB SELF-TEST
|
Yes | Install a new SJB. See Smart Junction Box (SJB) , . Test the system for normal operation. |
| No | The system is operating correctly at this time. The concern was caused by a fault in one of the output circuits. | ||