Communications Network - Troubleshooting: HS-Can: Notes
The HS-CAN uses an unshielded twisted pair cable of data (+) and data (-) circuits. The data (+) and the data (-) circuits are each regulated to approximately 2.5 volts during neutral or rested network traffic. As bus messages are sent on the data (+) circuit, voltage is increased by approximately 1.0 volt. Inversely, the data (-) circuit is reduced by approximately 1.0 volt when a bus message is sent. Multiple bus messages can be sent over the CAN circuits allowing multiple modules to communicate with each other. The HS-CAN is a high speed communication network used for the IC, the PCM, the ABS module, and 4X4 control module communications, and designed for real time information transfer and control. The HS-CAN network will not communicate while certain faults are present, but will operate with diminished performance with other faults present. The HS-CAN bus may remain operational when 1 of the 2 termination resistors are not present.
The HS-CAN operates at a maximum data transfer speed of 500 Kbps and is designed for real time information transfer and control. The network will remain operational, but at a degraded level when certain circuit faults are present.
The following fault chart describes the specific HS-CAN failures and their resulting symptom: