LEMON Manuals: Even more car manuals for everyone
Home >> Mazda >> 2008 >> RX-8 Touring, 1.3 3 >> Repair and Diagnosis (Single Page) >> Electrical >> Horns >> Instrumentation/Driver Info >> Data Monitoring And Recording Procedure >> Notes

Data Monitoring And Recording Procedure: Notes

  1. Connect the M-MDS or equivalent to the DLC-2.
    Fig 1: Locating DLC-2 Connector
    G04562621Courtesy of MAZDA MOTORS CORP.
  2. After the vehicle is identified, from the initial screen select the following items:
    • When using the IDS (laptop PC) 
      1. Select the "Tool Box" tab
      2. Select "DataLogger"
      3. Select "Modules"
      4. Select "IC"
    • When using the PDS (Pocket PC) 
      1. Select "Module tests"
      2. Select "IC"
      3. Select "DataLogger"
  3. Verify the data according to the monitor items.