LEMON Manuals: Even more car manuals for everyone
Home >> Mazda >> 2007 >> RX-8 Touring, 1.3 3 >> Repair and Diagnosis >> Electrical >> Charging Systems >> Charging System >> Generator Inspection >> Generator Inner Parts >> Rectifier

Generator Inner Parts: Rectifier

  1. Inspect for continuity of the diodes using a tester.
    Fig 1: Inspecting Continuity Of Diodes Using A Tester
    G04562935Courtesy of MAZDA MOTORS CORP.
    • If not as specified, replace the rectifier.
    RECTIFIER CONTINUITY CHART

    Tester Continuity
    Negative Positive
    E P1, P2, P3, P4 Yes
    B No
    P1, P2, P3, P4 E No
    B Yes
    Fig 2: Identifying Rectifier Terminals
    G04562936Courtesy of MAZDA MOTORS CORP.