IG-OFF Timer Function Inspection
IG-OFF TIMER FUNCTION INSPECTION CHART
| STEP |
INSPECTION |
ACTION |
| 1 |
- Close all doors.
- Turn the ignition switch from the ON to the LOCK position.
- Operate the power window main switch within 40 seconds
after turning the ignition switch to the LOCK position.
- Does the power window operate?
|
Yes |
Go to the next step. |
| No |
- Inspect the door switches and related wiring harness.
- If above parts are okay, replace the delayed power control module then go to the next step. (see DELAYED POWER CONTROL MODULE REMOVAL/INSTALLATION
.)
- If above parts are incorrect repair or replace malfunction part(s), then go to the next step.
|
| 2 |
- Close all doors.
- Turn the ignition switch from the ON to the LOCK position.
- Operate the power window main switch within 40 seconds
after turning the ignition switch to the LOCK position.
- Does the power window operate?
|
Yes |
- Inspect the door switches and related wiring harness.
- If above parts are okay, replace the delayed power control module then go to the next step. (see DELAYED POWER CONTROL MODULE REMOVAL/INSTALLATION
.)
- If above parts are incorrect repair or replace malfunction part(s), then go to the next step.
|
| No |
|
| 3 |
- Close all doors.
- Turn the ignition switch from the ON to the LOCK position.
- Operate the power window main switch after 40 seconds or later
from turning the ignition switch to the LOCK position.
- Does the power window operate?
|
Yes |
|
| No |
- IG-OFF timer function operation function is normal.
|