Instrument Cluster Configuration

  1. Connect the M-MDS to the DLC-2 connector.
    Fig 1: Locating DLC-2 Connector
    G04317682Courtesy of MAZDA MOTORS CORP.
  2. After the vehicle is identified, select the following items from the initial screen of the M-MDS.
    • When using the IDS (laptop PC)
      1. Select "Module Programming".
    • When using the PDS (Pocket PC)
      1. Select "Programming".
      2. Select "Module Programming".
  3. Select "Programmable Module Installation".
  4. Select "IC" and perform procedures according to directions on the M-MDS screen.
    • If odometer data is to be transferred to a new instrument cluster, perform the following procedure:
      1. Select "Programmable Parameters" from the menu.
      2. Select "Odometer Write", and perform the procedure following the screen.
      NOTE: During the odometer data writing procedure, As-Built Data (VIN and Vehicle Data) input is requested. Obtain the As-Built Sheet for the vehicle, and input the necessary data.
  5. Retrieve DTCs using the M-MDS and verify that there is no DTC present.