Instrument Cluster Configuration
- Connect the M-MDS to the DLC-2 connector.
- After the vehicle is identified, select the following items from the initial screen of the M-MDS.
- When using the IDS (laptop PC)
- Select "Module Programming".
- When using the PDS (Pocket PC)
- Select "Programming".
- Select "Module Programming".
- When using the IDS (laptop PC)
- Select "Programmable Module Installation".
- Select "IC" and perform procedures according to directions on the M-MDS screen.
- If odometer data is to be transferred to a new instrument cluster, perform the following procedure:
- Select "Programmable Parameters" from the menu.
- Select "Odometer Write", and perform the procedure following the screen.
NOTE: During the odometer data writing procedure, As-Built Data (VIN and Vehicle Data) input is requested. Obtain the As-Built Sheet for the vehicle, and input the necessary data.
- If odometer data is to be transferred to a new instrument cluster, perform the following procedure:
- Retrieve DTCs using the M-MDS and verify that there is no DTC present.
- If any DTC is present, perform applicable DTC inspection. See DTC TABLE [INSTRUMENT CLUSTER] .