Refrigerant Line Installation Note
- When installing a new cooler pipe or cooler hose, add a supplemental amount of ATMOS GU10 compressor oil into the refrigeration cycle.
Supplemental amount (approx. quantity)
5 ml {5 cc, 0.2 fl oz}: Cooler pipe
10 ml {10 cc, 0.3 fl oz}: Cooler hose
- Apply compressor oil to the O-rings and connect the joints.
- Tighten the joints.