Check Code Inspection
CHECK CODE 08 INSPECTION REFERENCE
| Check code 08 | TNS relay ON/OFF signal | ||
|---|---|---|---|
| STEP | INSPECTION CONDITION | DISPLAY | ACTION |
| 1 | Turn the headlight switch to the TNS position. (TNS relay ON) | Go to the next step. | |
Verify that the voltage of instrument cluster terminal 2l is B+
.
|
|||
| 2 | Turn the headlight switch off. (TNS relay OFF) | Verify that the voltage of the instrument cluster terminal 2l is 1.0 V or less
.
|
|
| Input signal to the instrument cluster is normal. | |||
CHECK CODE 12 INSPECTION REFERENCE
| Check code 12 | Speedometer display signal | ||
|---|---|---|---|
| INSPECTION CONDITION | DISPLAY | ACTION | |
| After selecting check code 12, wait for approx. 2 s . | The speedometer needle moves full scale then returns to approx. 60 km/h . | The speedometer is normal. | |
| Except above | Replace the instrument cluster. | ||
| - | |||
CHECK CODE 13 INSPECTION REFERENCE
| Check code 13 | Tachometer operation signal | ||
|---|---|---|---|
| INSPECTION CONDITION | DISPLAY | ACTION | |
| After selecting check code 13, wait for approx. 2 s . | The tachometer needle moves full scale then returns to approx. 3,000 rpm . | The tachometer is normal. | |
| Except above | Replace the instrument cluster. | ||
| - | |||
CHECK CODE 14 INSPECTION REFERENCE
| Check code 14 | Buzzer operation signal | ||
|---|---|---|---|
| INSPECTION CONDITION | DISPLAY | ACTION | |
| After selecting check code 14, wait approx. 2 s . | The buzzer sounds. | The buzzer is normal. | |
| The buzzer does not sound. | Replace the instrument cluster. | ||
CHECK CODE 16 INSPECTION REFERENCE
| Check code 16 | Fuel-level warning light flashing signal | ||
|---|---|---|---|
| INSPECTION CONDITION | DISPLAY | ACTION | |
| After selecting check code 16, wait approx. 2 s . | Fuel-level warning light flashes three times . | The fuel-level warning light is normal. | |
| Except above | Replace the instrument cluster. | ||
CHECK CODE 22 INSPECTION REFERENCE
| Check code 22 | Fuel level signal | ||
|---|---|---|---|
| STEP | INSPECTION CONDITION | DISPLAY | ACTION |
| 1 | Select check code 22 with the fuel gauge sender unit connector disconnected. | Go to the next step. | |
| Except above | Go to the Step 6. | ||
| 2 | Connect terminals 2U and 2W of the instrument cluster. | Go to the next step. | |
| Except above | Go to the Step 6. | ||
| 3 | Using the SST (Fuel and thermometer checker) or resistor, input 20 ohms between instrument cluster terminals 2U and 2W. | Go to the next step. | |
| Except above | Go to the Step 6. | ||
| 4 | Using the SST (Fuel and thermometer checker) or resistor, input 60 ohms between instrument cluster terminals 2U and 2W. | Go to the next step. | |
| Except above | Go to the Step 6. | ||
| 5 | Using the SST (Fuel and thermometer checker) or resistor, input 100 ohms between instrument cluster terminals 2U and 2W. | Inspect the fuel gauge sender unit. | |
| Except above | Go to the next step. | ||
| 6 | Inspect the wiring harness and connector between instrument cluster and fuel gauge sender unit.
|
||
CHECK CODE 23 INSPECTION REFERENCE
| Check code 23 | Fuel gauge operation signal | ||
|---|---|---|---|
| INSPECTION CONDITION | DISPLAY | ACTION | |
| After selecting check code 23, wait approx. 2 s . | The fuel gauge indicates status in the following order approx. every 2 s.
|
The fuel gauge is normal. | |
| Except above | Replace the instrument cluster. | ||
| Replace the instrument cluster. | |||
CHECK CODE 25 INSPECTION REFERENCE
| Check code 25 | Water temperature gauge operation signal | ||
|---|---|---|---|
| INSPECTION CONDITION | DISPLAY | ACTION | |
| After selecting check code 25, wait approx. 2 s . | The water temperature gauge indicates status in the following order approx. every 2 s
.
|
The water temperature gauge is normal. | |
| Except above | Replace the instrument cluster. | ||
| Replace the instrument cluster. | |||
CHECK CODE 26 INSPECTION REFERENCE
| Check code 26 | Odometer/tripmeter display signal | ||
|---|---|---|---|
| INSPECTION CONDITION | DISPLAY | ACTION | |
| Select check code 26. |
|
|
|
| Except above | Replace the instrument cluster. | ||
CHECK CODE 55 INSPECTION REFERENCE
| Check code 55 | Dimmer switch ON/OFF signal | ||
|---|---|---|---|
| STEP | INSPECTION CONDITION | DISPLAY | ACTION |
| 1 | After selecting the check code 55, press and hold the dimmer switch. (Dimmer switch ON) | Go to the next step. | |
| Replace the instrument cluster. | |||
| 2 | Release the dimmer switch. (Dimmer switch OFF) | Replace the instrument cluster. | |
| Input signal to the instrument cluster is normal. | |||
CHECK CODE 57 INSPECTION REFERENCE
| Check code 57 | Panel light control signal | ||
|---|---|---|---|
| INSPECTION CONDITION | DISPLAY | ACTION | |
| Turn the headlight switch to the TNS position. After selecting check code 57, wait approx. 2 s . |
Illumination light (hazard warning switch, center panel unit, etc.) flashes three times . | The panel light control signal is normal. | |
| Except above | Verify that the voltage of instrument cluster terminal F1 is B+
.
|
||
Diagnostic procedure
CHECK CODE 59 INSPECTION REFERENCE
| Check code 59 | CAN system/fuel system | ||
|---|---|---|---|
| STEP | INSPECTION | INDICATION | ACTION |
| 1 | The three digits number is indicated after selecting check code 59. Confirm the first digit from the right. | The CAN system is okay. Go to next step. |
|
| The DTC of CAN system is detected. Perform the DTC inspection. (See DTC TABLE[MULTIPLEX COMMUNICATION SYSTEM] )
Go to next step. |
|||
| 2 | Confirm the second digit from the right. | The wiring harnesses between the fuel gauge sender unit and instrument cluster are okay. Go to next step. |
|
Inspect following parts.
Go to next step. |
|||
| 3 | Confirm the third digit from the right. | The fuel pulse signal from the PCM is okay. | |
| Inspect the PCM. (See ON-BOARD DIAGNOSTIC TEST[L3 WITH TC] , PCM INSPECTION[L3 WITH TC] )
|
|||