Front Side
- Apply battery positive voltage and connect the ground to power window motor terminals E and F, and then inspect the power window motor operation.
- If the power window motor does not operate as indicated in the table, replace it.CAUTION:
- If the power window motor temperature is high, the motor may not rotate due to the motor internal bimetal function. Leave it untouched for about 3 min to cool it down, then reinspect.
TEMPERATURE DESCRIPTIONOperation Terminal F E Open B+ Ground Close Ground B+ - If the power window motor does not operate as indicated in the table, replace it.
- Connect the battery positive voltage to power window motor terminal D and connect terminal C to ground.
- Operate the power window motor and measure the voltage at terminals A and B.
- If there is any malfunction, replace the power window motor.
Voltage
- Pulse: max. 12 V/min. 0 V