LEMON Manuals: Even more car manuals for everyone
Home >> Mazda >> 2007 >> B3000 Base, Automatic >> Repair and Diagnosis >> External Pages >> Different car >> Section 10 (Engine Controls - Basic Testing - 2.3L) >> Fuel System >> Fuel Pressure >> Fuel Pressure Regulator

Fuel Pressure Regulator

WARNING: This page is about a different car, the 1997 Mazda Millenia. However, it is still accessible from the selected car via links, so may be relevant.
  1. Disconnect negative battery cable. Install fuel pressure gauge in fuel supply line. Reconnect negative battery cable.
  2. Start and operate engine at idle. Ensure vacuum is available to pressure regulator. Observe fuel pressure with vacuum hose connected and disconnected at fuel pressure regulator. See REGULATED FUEL PRESSURE  table. If fuel pressure is not as specified, check fuel pressure regulator hold pressure. See FUEL PRESSURE REGULATOR HOLD PRESSURE heading below.
REGULATED FUEL PRESSURE

Model @ Idle W/Vacuum psi (kg/cm2 ) @ Idle W/O Vacuum psi (kg/cm2 )
Millenia 2.3L 30-41 (2.1-2.9) 38-48 (2.7-3.4)