Possible Causes
- Fuse
- Circuit (R) open
- SJB
CAUTION:
- Use the correct probe adaptor(s) when making measurements. Failure to use the correct probe adaptor(s) may damage the connector.
ALL DOOR LOCKS ARE INOPERATIVE - PINPOINT TEST REFERENCE
| PINPOINT TEST 2 | ALL DOOR LOCKS ARE INOPERATIVE | ||
|---|---|---|---|
| STEP | INSPECTION | ACTION | |
| 1 | CHECK CIRCUIT (R) FOR AN OPEN
|
Yes | Go to next step. |
| No | Verify the battery junction box (BJB) fuse 1 (40A) is OK. If OK, repair circuit (R) for an open. Clear the DTCs. Repeat the self-test. | ||
| 2 | CHECK FOR CORRECT SJB OPERATION
|
Yes | Install a new SJB. See SMART JUNCTION BOX (SJB) , . Clear the DTCs. Repeat the self-test |
| No | The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector. Clear the DTCs. Repeat the self-test. | ||