Diagnostic procedure

DIAGNOSTIC PROCEDURE

STEP INSPECTION ACTION
1
  • Inspect the following:
    • Engine coolant level
    • Coolant leakage
    • Water and anti-freeze mixture
    • Radiator condition
    • Collapsed or restricted radiator hoses
    • Radiator pressure cap
    • Overflow system
    • Fan rotational direction
    • Fuses
  • Are all items normal?
Yes Go to the next step.
No Service as necessary.
Repeat Step 1.
2
  • Connect M-MDS to DLC-2.
  • Turn ignition switch to ON position (Engine OFF).
  • Retrieve any DTCs.
  • Are there any DTCs displayed?
Yes DTC is displayed: 
  • Go to appropriate DTC test.
No No DTC is displayed: 
  • Go to the next step.
3
  • Start engine and run it at idle speed.
  • Turn A/C switch on.
  • Does A/C compressor engage?
Yes Go to step 5.
No Inspect the following and repair or replace as necessary:
  • Refrigerant charging amount
  • Open circuit between A/C relay and PCM terminal 1AW
  • Seized A/C magnetic clutch
  • A/C magnetic clutch malfunction
    • If all items are normal, Inspect the following:
      • Refrigerant pressure switch operation
      • Evaporator temperature sensor and A/C amplifier
      • A/C switch is stuck open.
      • Open or short circuit between refrigerant pressure switch and PCM terminal 1AN
      • Open circuit of blower motor fan switch and resistor (if blower motor does not operate)
4
  • Start engine and run it at idle speed.
  • Turn A/C switch on and set blower fan any speed.
  • Do cooling fan and condenser fan operate?
Yes Go to the next step.
No Cooling fan motor does not operate: 
  • Inspect for following:
    • Cooling fan motor malfunction
    • Cooling fan motor GND open circuit
    • Open circuit between cooling fan motor and fan control module

Condenser fan motor does not operate: 
  • Inspect for the following:
    • Condenser fan motor malfunction
    • Condenser fan motor GND open circuit
    • Open circuit between condenser fan motor and fan control module

Both cooling fan and condenser fan do not operate: 
  • Inspect for the following:
    • Fan control module malfunction
    • Fan control module GND open circuit
    • Open circuit between fan control module and cooling fan relay
5
  • Is drive belt normal?
Yes Go to the next step.
No Replace drive belt.
6
  • Is there any leakage around heater unit in passenger compartment?
Yes Inspect and service heater for leakage.
No Go to the next step.
7
  • Is there any leakage at coolant hoses and/or radiator?
Yes Replace malfunctioning part.
No Go to the next step.
8 Yes Engine coolant temperature and thermostat are normal. Inspect engine block for leakage or blockage.
No Access ECT PID on M-MDS.
Inspect both ECT PID and temperature gauge readings.
  • If temperature gauge on instrument cluster indicates normal range but ECT PID is not same as temperature gauge reading, inspect ECT sensor.
  • If temperature gauge on instrument cluster indicates overheating but ECT PID is normal, inspect temperature gauge and heat gauge unit.
9
  • Verify test results.
    • If normal, return to diagnostic index to service any additional symptoms.
    • If malfunction remains, inspect related Service Bulletins and/or On-line Repair Information and perform repair or diagnosis.
      • If vehicle is repaired, troubleshooting completed.
      • If vehicle is not repaired or additional diagnostic information is not available, reprogram PCM if later calibration is available. Retest.