PID/DATA Monitor and Record Procedure
NOTE:
The PID/DATA MONITOR function monitors the calculated value of the input/output signals the PCM. Therefore, an output device malfunction is not directly indicated as a malfunction of the monitored value for the output device. If a monitored value of an output device is out of specification, inspect the monitored value of the input device related to the output control.
- Connect the M-MDS to the DLC-2.
- After the vehicle is identified, select the following items from the initial screen of the M-MDS.
- When using the IDS (laptop PC)
- Select the "Toolbox" tab.
- Select "Datalogger".
- Select "Modules".
- Select "PCM".
- When using the PDS (Pocket PC)
- Select "Module Tests".
- Select "PCM".
- Select "Datalogger".
- When using the IDS (laptop PC)
- Select PID from the PID table.
- Verify the PID data according to the directions on the screen.