On-Board System Readiness Tests Access Procedure
- Connect the M-MDS to the DLC-2.
- After the vehicle is identified, select the following items from the initial screen of the M-MDS.
- When using the IDS (laptop PC)
- Select the "Toolbox" tab.
- Select "Powertrain".
- Select "OBD Test Modes".
- Select "Mode 1 Powertrain Data".
- When using the PDS (Pocket PC)
- Select "OBDII Modes".
- Select "Mode 1 Powertrain Data".
- Select "PCM".
- When using the IDS (laptop PC)
- Then, select the "***SUP" and "***EVAL" PIDs in the PID selection screen.
- Monitor those PIDs and check if system monitor is completed.