Instrument Cluster Configuration
NOTE:
- If all the following conditions are met, the odometer data (total traveled, distance) in the previous instrument cluster is automatically transferred to a new instrument cluster during the configuration. If any of the conditions are not met, odometer-data transfer cannot be performed.
- Previous Instrument Cluster
- No malfunction (Configuration data can be read using the M-MDS)
- New Instrument Cluster
- Odometer display is less than 100 km
- Odometer has no malfunction
- Previous Instrument Cluster
- Connect the M-MDS or equivalent to the DLC-2.
- After the vehicle is identified, from the initial screen select the following items:
- When using the IDS (laptop PC)
- Select "Module Programming"
- When using the PDS (Pocket PC)
- Select "Programming"
- Select "Module Programming"
- When using the IDS (laptop PC)
- Select "IC" and perform procedures according to directions on the M-MDS screen.
- If odometer data is to be transferred to a new instrument cluster, perform the following procedure:
- Select "Programmable Parameters" from the menu.
- Select "Odometer Write", and perform the procedure following the screen.
NOTE:- During the odometer data writing procedure, As-Built Data (VIN and Vehicle Data) input is requested. Obtain the As-Built Sheet for the vehicle, and input the necessary data.
- If odometer data is to be transferred to a new instrument cluster, perform the following procedure:
- After the instrument cluster configuration, perform the wheel unit ID registration. (See WHEEL UNIT ID REGISTRATION ).
- Retrieve DTCs using the M-MDS and verify that there is no DTC present.
- If any DTC is present, perform applicable DTC inspection. (See DTC TABLE [INSTRUMENT CLUSTER] ).