LEMON Manuals: Even more car manuals for everyone
Home >> Mazda >> 2007 >> 3 i, 2.0 G, Standard >> Repair and Diagnosis >> Engine Performance >> Fuel Delivery >> Fuel System (LF, L3) >> After Service Precaution >> Fuel Leakage Inspection >> Without using M-MDS

Without using M-MDS

  1. Disconnect the negative battery cable.
  2. Remove the fuel pump relay.
    CAUTION:
    • Be careful to short the specified terminal as shorting the wrong terminal of the main fuse block may cause a malfunction.
      Fig 1: Identifying Fuel Pump Relay And Main Fuse Block
      G04954793Courtesy of MAZDA MOTORS CORP.
  3. Using a jumper wire, short fuel pump relay terminals C and D and connect the negative battery cable to start the fuel pump.
  4. Verify that there is no fuel leakage from the pressurized parts.
    • If there is leakage, replace the fuel hoses and clips.
    • If there is damage on the seal on the fuel pipe side, replace the fuel pipe.

    Standard 

    There shall be no leakage after 5 min. 

  5. After reinstallation, repeat step  3- 4 in the fuel leakage inspection.
    Fig 2: Identifying Fuel Pump Relay Terminals
    G04954794Courtesy of MAZDA MOTORS CORP.