Diagnostic procedure
DTC U2030 DIAGNOSTIC PROCEDURE
| STEP | INSPECTION | ACTION | |
|---|---|---|---|
| 1 | INSPECT RAIN SENSOR CONNECTOR
|
Yes | Repair or replace the terminal, then go to Step 6. |
| No | Go to the next step. | ||
| 2 | INSPECT PJB CONNECTOR
|
Yes | Repair or replace the terminal, then go to Step 6. |
| No | Go to the next step. | ||
| 3 | INSPECT RAIN SENSOR CIRCUIT FOR OPEN CIRCUIT
|
Yes | Go to the next step. |
| No | Repair or replace the wiring harness for a possible open circuit, then go to Step 6. | ||
| 4 | INSPECT RAIN SENSOR SIGNAL CIRCUIT FOR SHORT TO GND
|
Yes | Repair or replace the wiring harness for a possible short to GND, then go to Step 6. |
| No | Go to the next step. | ||
| 5 | INSPECT RAIN SENSOR SIGNAL CIRCUIT FOR SHORT TO POWER SUPPLY
|
Yes | Repair or replace the wiring harness for a possible short to power supply, then go to the next step. |
| No | Replace the Rain sensor, then go to the next step. (See RAIN SENSOR REMOVAL/INSTALLATION .) |
||
| 6 | VERIFY TROUBLESHOOTING COMPLETED
|
Yes | Replace the PJB. (See PASSENGER JUNCTION BOX (PJB) REMOVAL/INSTALLATION .) |
| No | Troubleshooting completed. | ||