Possible Causes
- circuit (R/LB) short to voltage
- accessory delay relay
- SJB
DELAYED ACCESSORY NOT TURN OFF - PINPOINT TEST REFERENCE
| PINPOINT TEST 8 | THE DELAYED ACCESSORY DOES NOT TURN OFF | ||
|---|---|---|---|
| STEP | INSPECTION | ACTION | |
| 1 | CHECK FOR STUCK/STICKING ACCESSORY DELAY RELAY
|
Yes | GO to step 3. |
| No | Go to next step. | ||
| 2 | CHECK THE ACCESSORY DELAY RELAY
|
Yes | GO to step 4. |
| No | INSTALL a new accessory delay relay. TEST the system for normal operation. | ||
| 3 | CHECK CIRCUIT (R/LB) FOR A SHORT TO POWER
|
Yes | REPAIR the circuit. CLEAR the DTCs. TEST the system for normal operation. |
| No | Go to next step. | ||
| 4 | CHECK FOR CORRECT SJB OPERATION
|
Yes | INSTALL a new SJB. See SMART JUNCTION BOX (SJB) for the removal and installation procedure. TEST the system for normal operation. |
| No | The system is operating correctly at this time. Concern may have been caused by a loose or corroded connector. TEST the system for normal operation. | ||