Pinpoint Test 3: No Power In Start/On
NO POWER IN START/ON - PINPOINT TEST REFERENCE
| PINPOINT TEST 3 | NO POWER IN START/ON | ||
|---|---|---|---|
| STEP | INSPECTION | ACTION | |
| 1 | CHECK CIRCUIT (LG/V) FOR AN OPEN OR SHORT TO GROUND
|
Yes | Go to next step. |
| No | REPAIR circuit (LG/V) for an open or a short to ground. CLEAR the DTCs. REPEAT the self-test. | ||
| 2 | CHECK THE IGNITION SWITCH
|
Yes | Go to next step. |
| No | INSTALL a new ignition switch. See IGNITION SWITCH . CLEAR the DTCs. REPEAT the self-test. | ||
| 3 | CHECK FOR CORRECT SJB OPERATION
|
Yes | INSTALL a new SJB. See SMART JUNCTION BOX (SJB) . |
| No | The system is operating correctly at this time. Concern may have been caused by a loose or corroded connector. CLEAR the DTCs. REPEAT the self-test. | ||