OSC - Bench Mode:
The BENCH MODE is functional only when the gear selector is in PARK or NEUTRAL. The BENCH MODE may be used when the engine is either ON (running) or OFF. The BENCH MODE allows the technician to function the following components:
- SS1 - Directs the PCM to command the shift solenoid A OFF or ON
- SS2 - Directs the PCM to command the shift solenoid B OFF or ON
- SS2_AMP - Directs the PCM to command the current to the 3-2 timing/coast clutch solenoid
- TCC - Directs the PCM to command the torque converter solenoid OFF or ON (OFF = 0% duty cycle and ON = 100% duty cycle)
- LINEDSD - Directs the PCM to command the line pressure to either 50, 75, 100, 125, 150, 175, 200 psi. The PCM commands the appropriate PCA current to obtain the commanded line pressure.