Keyless Control Module Inspection [Without Advanced Keyless System]: Notes
- Measure the voltage or inspect for continuity according to TERMINAL VOLTAGE MEASUREMENT CONDITION REFERENCE .
- If the voltage is not as specified in TERMINAL VOLTAGE MEASUREMENT CONDITION REFERENCE , inspect the parts under "Inspection item(s)".
- If the system does not work properly even though the parts or related wiring harnesses do not have any malfunction, perform symptom troubleshooting.