DTC P2407: Notes
DTC P2407 DETECTION CONDITION AND POSSIBLE CAUSES
| DTC P2407 |
EVAP system leak detection pump sensor circuit intermittent |
| DETECTION CONDITION |
- The PCM monitors pump load current (EVAP line pressure), while EVAP leak monitor is operating. When either of the following is detected 6 times or more
successively, the PCM determines EVAP system leak detection pump heater has a malfunction:
- While obtaining the reference current value, the change in pump load current exceeds the specification.
- After obtaining the reference current value, the pump load current is kept lower than the maximum pump load current for more than the specified time.
Diagnostic support note
- This is a intermittent monitor (CCM).
- MIL illuminates if PCM detects above malfunction condition in two consecutive drive cycles or in one drive cycle while DTC for the same malfunction has been stored in PCM.
- PENDING CODE is available if PCM detects the above malfunction condition during first drive cycle.
- FREEZE FRAME DATA is available.
- DTC is stored in PCM memory.
|
| POSSIBLE CAUSE |
- EVAP system leak detection pump heater malfunction
- PCM malfunction
|