NONRETURN Valve Inspection
- Remove the fuel-filler pipe. (See FUEL TANK REMOVAL/INSTALLATION )
- Move the valve and verify that the valve opens to 90°.
- If it does not open, replace the fuel-filler pipe.
- Verify that the nonreturn valve returns to the normal position by spring force.
- If it does not return, replace the fuel-filler pipe.