Circuit Open/Short Inspection
- Inspect the following wiring harness for an open or short circuit (Continuity check).
Open Circuit
- If there is no continuity, the circuit is open. Repair or replace the harness.
- GND Circuit (FP Connector Terminal D And Body GND)
- Power Circuit (Fuel Pump Relay (FP RLY) Connector Terminal C And FP Connector Terminal B Through Common Connector)
Short Circuit
- If there is no continuity, the circuit is shorted. Repair or replace the harness.
- FP RLY Connector Terminal C And FP Connector Terminal B Through Common Connector to GND
- If there is no continuity, the circuit is open. Repair or replace the harness.