Heated Oxygen Sensor (HO2S) Monitor
The HO2S monitor is an on-board strategy designed to monitor the HO2S sensors for a malfunction or deterioration which can affect emissions. The fuel control or Stream 1 HO2S sensors are checked for proper output voltage and response rate (the time it takes to switch from lean to rich and vice versa). Stream 2 HO2S sensors used for catalyst monitor, and Stream 1 HO2S sensors used for FAOS (Fore-Aft Oxygen Sensor) control are also monitored for proper output voltage. The fuel system monitor and misfire detection monitor must also have completed successfully before the HO2S monitor is enabled.
- The HO2S sensor senses the oxygen content in the exhaust flow and outputs a voltage between zero and 1.0 volt. Lean of stoichiometric (air/fuel ratio of approximately 14.7:1), the HO2S will generate a voltage between zero and 0.45 volts. Rich of stoichiometric, the HO2S will generate a voltage between 0.45 and 1.0 volt. The HO2S monitor evaluates the Stream 1 (fuel control), Stream 2 (catalyst monitor) and the Stream 3 HO2S (FAOS control) for proper function.
- Once the HO2S monitor is enabled, the Stream 1 HO2S signal voltage amplitude and response frequency are checked. Excessive voltage is determined by comparing the HO2S signal voltage to a maximum calibratable threshold voltage. A fixed frequency closed loop fuel control routine is executed and the Stream 1 HO2S voltage amplitude and output response frequency are observed. A sample of the Stream 1 HO2S signal is evaluated to determine if the sensor is capable of switching or has a slow response rate. An HO2S heater circuit fault is determined by turning the heater on and off and looking for a corresponding change in the output state monitor (OSM) and by measuring the current going through the heater circuit. Since the 2002 Model Year, vehicles will monitor the HO2S signal for a high voltage in excess of 1.5 volts.
- The MIL is activated after a fault is detected on two consecutive drive cycles.
The HO2S Monitor DTCs can be categorized as follows:
- HO2S signal circuit malfunction - P0131, P0136, P0151, P0156.
- HO2S slow response rate - P0133, P0153.
- HO2S circuit high voltage - P0132, P0138, P0144, P0152, P0158, P0164.
- HO2S heater circuit malfunction - P0135, P0141, P0155, P0161, P0147, P0167.
- HO2S heater current malfunction - P0053, P0054, P0055, P0059, P0060, P0061.
- Downstream HO2S not running in on-demand self test - P1127.
- Swapped HO2S connectors - P0040, P0041, P1128, P1129, P2278.
- HO2S lack of switching - P1131, P1132, P1151, P1152, P2195, P2196, P2197, P2198.
- HO2S lack of switching (sensor indicates lean) - P1137, P1157, P2270, P2272, P2274, P2276.
- HO2S lack of switching (sensor indicates rich) - P1138, P1158, P2271, P2273, P2275, P2277.