Magnetic Switch
- Inspect for continuity between terminals (S) and (M) using an ohmmeter. If there is no continuity, replace the magnetic switch. See Fig 1.
- Inspect for continuity between terminal (S) and the body using an ohmmeter. If there is no continuity, replace the magnetic switch. See Fig 2.
- Verify that there is no continuity between terminals (M) and (B) using an ohmmeter. If there is continuity, replace the magnetic switch. See Fig 3.
Courtesy of MAZDA MOTORS CORP.
Courtesy of MAZDA MOTORS CORP.
Courtesy of MAZDA MOTORS CORP.