Evaporative Emissions System Leak Test
Connect Evaporative Emissions System Leak Tester (134-00056) to EVAP test port. Close Canister Vent Control (CVC) solenoid. See CANISTER VENT CONTROL SOLENOID CLOSING PROCEDURE . Pressurize EVAP system to 14 in. H2 O (3.48 kPa). Monitor system pressure for 2 minutes. EVAP system pressure should not fall to less than 8 in. H2 O (2 kPa). Repair leaks as necessary. Repeat EVAP system leak test until system pressure remains more than 8 in. H2 O (2 kPa) after 2 minutes.