Freeze Frame PID Data Access Procedure
- Apply parking brake. Place shift lever in Park (A/T) or Neutral (M/T). Block wheels. Turn off all electrical accessories. Ensure engine is at normal operating temperature.
- Perform visual inspection. Ensure air cleaner and inlet ducts are clean, and system wiring harness is properly connected. Check for bent or broken connector terminals and corroded or loose wires. Check PCM, sensors and actuators for physical damage. Check engine coolant for proper level and mixture. Check for proper transmission fluid level and quality.
- Connect WDS or equivalent scan tool to DLC-2 located at left side of steering column under instrument panel. Follow scan tool manufacturer's operating instructions to connect equipment and record Freeze Frame PID Data.