Pressure Regulator Control (PRC) Solenoid Valve
NOTE:
PRC solenoid valve is not used on Miata or MPV.
Disconnect vacuum hose from PRC solenoid valve. See PRC SOLENOID VALVE LOCATIONS table. Apply air pressure to PRC solenoid valve port "B". See Fig 1 . Air should flow from port "C" only. Using fused jumper wires, apply battery voltage to solenoid terminals. Apply air pressure to PRC solenoid valve port "B". Air should flow through PRC solenoid valve air filter (port "A") only. If PRC solenoid valve operation is not as specified, replace valve.
PRC SOLENOID VALVE LOCATIONS
| Application | Location | |
|---|---|---|
| Millenia | ||
| 2.3L | Top Right Side Of Engine | |
| 2.5L | Mounted On Top Of Air Cleaner | |
| Protege & Protege5 | Mounted On Intake Plenum | |
| 626 | ||
| 2.0L | Mounted On Intake Plenum | |
| 2.5L | Mounted On Top Of Air Cleaner | |