Refrigerant Pressure Switch Inspection
- Install the manifold gauge set.
- Disconnect the refrigerant pressure switch connector.
- Verify the high- and low-pressure side reading of manifold gauge.
- Check for continuity between terminals of the refrigerant pressure switch.
- If not as specified, replace the refrigerant pressure switch.