Trouble Shooting Precautions
Observe the following precautions when trouble shooting or testing charging system:
- DO NOT reverse battery cable connections. Rectifier will be damaged.
- Battery voltage should always exist at generator terminal "B".
- DO NOT ground generator terminal "L" while engine is running.
- DO NOT start engine with generator disconnected.