Door Lock Control Module
Remove lower instrument panel cover. Locate door lock control module behind center of instrument cluster. Leave door lock control module connector attached. Using DVOM, measure voltage at specified terminals of door lock control module connector (backprobe connector). See Fig 1 . Disconnect door lock control module connector and check for continuity at terminals "K", "L" and "N" (ground). If voltage measurements or continuity are not as specified, check related components and wiring harnesses. If related components and wiring harnesses are okay, but system is still not functioning properly, replace door lock control module.