DTC P1634: Generator Terminal B Circuit Open: Condition
PCM monitors input voltage from generator and battery. DTC is set when engine is running and generator voltage is more than 17 volts and battery voltage is less than 11 volts for 5 seconds. Possible causes are:
- Open circuit.
- Battery malfunction.