Airflow Mode Inoperative

WARNING: This page is about a different car, the 1997 Mazda MX-6 and 1997 Mazda 626. However, it is still accessible from the selected car via links, so may be relevant.

Test airflow mode actuator. See ACTUATORS  . If actuator is okay, disconnect airflow mode actuator connector and heater control panel connector. Check continuity of wiring harness between control panel connector and airflow mode actuator connector. See AIRFLOW MODE  ACTUATOR WIRING HARNESS TEST table. If continuity is as specified, replace heater control panel. If continuity is not as specified, repair appropriate open wire between connectors.

AIRFLOW MODE ACTUATOR WIRING HARNESS TEST

Terminal Wire Color (1) Continuity
White Yes
White/Black Yes
White/Yellow Yes
White/Green Yes
White/Blue Yes
Yellow Yes
Yellow/White Yes
Yellow/Black Yes
Yellow/Green Yes
(1) Check continuity of wiring harness between heater control panel and airflow mode actuator.